Diffusion and Heat Transfer Characteristics and Effects of Gas Leakage from Buried Natural Gas Pipelines

Fan-xi BU , Zhuo-ran LÜ , Xin-qi GAO , Wen-yu WANG , Zuo-nan HUANG , Zhi-hua WANG

Science Technology and Engineering ›› 2026, Vol. 26 ›› Issue (31) : 13462 -13471.

PDF
Science Technology and Engineering ›› 2026, Vol. 26 ›› Issue (31) : 13462-13471 DOI: 10.12404/j.issn.1671-1815.2600175
research-article
Diffusion and Heat Transfer Characteristics and Effects of Gas Leakage from Buried Natural Gas Pipelines
Author information +
History +
PDF

Abstract

Buried natural gas pipelines are susceptible to leakage induced by natural or anthropogenic factors, and such leakage events can pose significant safety hazards. To address the insufficient consideration of gas-soil heat transfer characteristics and the lack of theoretical guidance for the deployment of distributed fiber optic detection systems, numerical simulation was adopted to investigate the effects of pipeline transmission temperature and ambient soil temperature on natural gas leakage diffusion behavior and the corresponding fiber optic alarm response performance. The results show that, compared with the adiabatic model, the mass flow rate at the leakage orifice increases when the gas-soil heat transfer characteristics are fully considered, and the consistency between simulation results and experimental data is significantly improved. The mass flow rate at the leakage orifice increases as the pipeline transmission temperature decreases, while the influence of soil temperature on the leakage mass flow rate is relatively limited, with a difference of less than 1%. The diffusion range of leaked natural gas decreases with the increase of pipeline transmission temperature, and expands with the rise of soil temperature. Both the decrease in pipeline transmission temperature and the increase in soil temperature will lead to a delay in the fiber optic alarm response: specifically, the alarm response time is extended by 58.1 s when the pipeline transmission temperature decreases by 30 K, and the response time is prolonged by 10 s when the soil temperature increases by 20 K. The maximum error of the buried fiber optic alarm time prediction model is 10%, with an average error of 4.18%, which verifies the high accuracy of the prediction results. It is concluded that thermal characteristics have a significant impact on the entire leakage evolution process. This result provides a solid theoretical basis for the division of leakage emergency response zones and the optimization of distributed fiber optic detection system deployment schemes.

Graphical abstract

Keywords

natural gas leakage / numerical simulation / soil temperature distribution / optical fiber detection

Cite this article

Download citation ▾
Fan-xi BU, Zhuo-ran LÜ, Xin-qi GAO, Wen-yu WANG, Zuo-nan HUANG, Zhi-hua WANG. Diffusion and Heat Transfer Characteristics and Effects of Gas Leakage from Buried Natural Gas Pipelines. Science Technology and Engineering, 2026, 26(31): 13462-13471 DOI:10.12404/j.issn.1671-1815.2600175

登录浏览全文

4963

注册一个新账户 忘记密码

References

Funding

PDF (13892KB)

0

Accesses

0

Citation

Detail

Sections
Recommended

/

〈 〉