Reason and Solution of Three-phase Unbalance of Auxiliary Motor Induced by No-load Closing of Transformer in Nuclear Power Plant

Shao-jiu ZHANG , Yao-kun TAN , Yi JIANG , Chen-hui HUANG , Yu-cai WU , Yan-ze LIU

Science Technology and Engineering ›› 2025, Vol. 25 ›› Issue (35) : 15114 -15124.

PDF
Science Technology and Engineering ›› 2025, Vol. 25 ›› Issue (35) : 15114-15124 DOI: 10.12404/j.issn.1671-1815.2501377
research-article
Reason and Solution of Three-phase Unbalance of Auxiliary Motor Induced by No-load Closing of Transformer in Nuclear Power Plant
Author information +
History +
PDF

Abstract

Excitation inrush current is generated during no-load switching of the main transformer in a nuclear power plant. This current may cause sympathetic inrush in adjacent operating transformers and increase the three-phase current imbalance in auxiliary motors. It may also lead to misoperation of three-phase unbalanced protection. To address these issues, an expression for the inrush current during no-load closing of transformers was derived, with remanence introduced as an adjustable parameter. The findings show that pre-magnetizing the main transformer in the opposite direction to the closing magnetic flux can cancel out the residual magnetism and bias magnetism. Thus, the inrush current was effectively suppressed. Based on the analysis of the sympathetic inrush current expressions, it was concluded that the system impedance value greatly influences the degree of three-phase unbalance caused by the inrush. A simulation model of the primary circuit of a nuclear power plant with six generating units was constructed using PSCAD. The magnetizing inrush current, the sympathetic inrush current, and the unbalanced state of the medium voltage motor associated with the adjacent transformer during the no-load closing process. The effects of motor load levels and system contact impedance on the motor's three-phase unbalanced were analyzed. The results demonstrate that pre-magnetization can effectively reduce the three-phase unbalance and prevent misoperation of the asynchronous motor protection. This approach offers a new solution for protecting asynchronous motors affected by no-load closing of the main transformer.

Keywords

no-load closing / transformer / excitation inrush current / sympathetic inrush current / inrush current suppression

Cite this article

Download citation ▾
Shao-jiu ZHANG, Yao-kun TAN, Yi JIANG, Chen-hui HUANG, Yu-cai WU, Yan-ze LIU. Reason and Solution of Three-phase Unbalance of Auxiliary Motor Induced by No-load Closing of Transformer in Nuclear Power Plant. Science Technology and Engineering, 2025, 25(35): 15114-15124 DOI:10.12404/j.issn.1671-1815.2501377

登录浏览全文

4963

注册一个新账户 忘记密码

References

Funding

PDF (1910KB)

18

Accesses

0

Citation

Detail

Sections
Recommended

/

〈 〉