Precise measurement of weak currents below the milliampere level in power supply systems has long been a gap. In recent years, magnetometers based on quantum technology and the atomic spin principle have emerged and can indirectly achieve precise measurement of small currents; related methods and experimental studies have also been gradually carried out. On the basis of the physical principle and technical characteristics of spin-exchange relaxation-free (SERF) atomic magnetometers, this paper investigates the practical technologies required to apply SERF atomic magnetometers to precise measurement of sub-milliampere weak currents, including gas-cell temperature control, laser power and frequency locking, and miniaturization, together with their implementation schemes. A small-current measurement system based on a SERF atomic magnetometer was then built. Experimental results confirm that the system can respond in real time to weak-current signals under test in the 1~100 Hz range, that the measurement results are consistent at multiple preset frequency points, and that there is a good linear relationship between the current under test and the magnetic-field response; thus, weak currents in the range of 10 nA~400 μA were successfully measured. This result provides a feasible technical approach for precise measurement and quantum-based traceability of weak currents below the milliampere level in power supply systems, and lays an experimental foundation for subsequent engineering applications.
BAI Jing-fen, GE Ya-nan, ZHANG Zheng-ming.
Weak Current Measurement Technique Based on SERF Atomic Magnetometer[J].
Science Technology and Engineering, 2026, 26(31): 13519-13526 DOI:10.12404/j.issn.1671-1815.2507837
实际使用中,半导体激光器工作时会产生大量热量,导致其输出特性发生变化。温度变化会影响阈值电流与输出功率,进而影响激光器的频率稳定性。目前,为实现激光频率与功率的稳定,通常采用饱和吸收光谱稳频(saturated absorption spectroscopy frequency stabilization,SASFS)和塞曼调制稳频(Zeeman modulation for frequency stabilization,ZMFS)两种方案。
电流在磁屏蔽系统内产生的磁场方向如图3所示。由图3可知,原子磁力计电流测量系统包括电流源、SERF原子磁力仪探头、探头控制系统、上位机、磁屏蔽。电流源用于产生不同频率及幅值的电流信号,在性能测试过程中使用已知频率和幅值的电流作为输入信号。SERF原子磁力仪探头及控制系统用于测量电流产生的磁场,并将信号输出给上位机,上位机用来控制探头状态及记录分析探头获取的磁场信号。该系统采用五层坡莫合金的磁屏蔽来屏蔽地磁场和杂散磁场对原子磁力仪探头的影响。直导线在磁屏蔽系统内长度为600 mm,探头的磁敏感单元距离直导线16 mm,磁敏感单元的体积为5 mm × 5 mm × 5 mm。
LiWeipeng, WeiXiaogang, YangRenfu. Development status of weak current metrology calibration technique based on atomic magnetic field detection[J]. Journal of Astronautic Metrology and Measurement, 2023, 43(5): 36-40.
ChenDayong, MiaoPeixian, ShiYanchao, et al. Measurement of noise of current source by pumpprobe atomic magnetometer[J]. Acta Physica Sinica, 2022, 71(2): 91-97.
MiaoPeixian. Measurement of 10 kHz sinusoidal alternating current by pumpprobe atomic magnetometer[J]. Vacuum and Cryogenics, 2022, 28(5): 592-600.
[7]
LiG Z, XinQ, GengX X. Current sensor based on an atomic magnetometer for DC application[J]. Chinese Optics, 2020, 18(3): 031202.
[8]
KossP A, DinaniR T, BienstmanL, et al. Opticalmagnetometrybased current source[J]. Physical Review Applied, 2021, 16(1): 014011.
[9]
ShenL, ZhangR, WuT, et al. Suppression of current source noise with an atomic magnetometer[J]. Review of Scientific Instruments, 2020, 91(8): 084701.
[10]
ZhaoN, ZhangL L, YangY B, et al. Characterizing current noise of commercial constant current sources by using an optically pumped rubidium atomic magnetometer[J]. Review of Scientific Instruments, 2023, 94(9): 095001.
[11]
陈建军, 魏薇. 大学基础物理学[M]. 北京: 高等教育出版社, 2015.
[12]
ChenJianjun, WeiWei. University fundamental physics[M]. Beijing: Higher Education Press, 2015.
WangYu, ZhaoWeiyu, KangXiangyu, et al. The latest development and application of SERF atomic magnetometer: a review[J]. Optical Instruments, 2021, 43(6): 77-86.
HuFeng. Study of the effective field based on exchange interaction in Pr: YIG and Gd3Ga5O12 at low temperature[D]. Beijing: China University of Mining and Technology-Beijing, 2014.
LiZhenhua, CuiJiuxi, LuHeping, et al. Review of wideband and wide dynamic range current measurement techniques in power systems[J]. High Voltage Engineering, 2024, 50(8): 3421-3439.
QiMeng, LiKaicheng, SunJian, et al. Research on DSP based error measurement for electromagnetic instrument transformer[J]. Electrical Measurement and Instrumentation, 2014, 51(4): 14-17, 72.
XuChangbao, GaoJipu, LuCaijiang, et al. Research on the transient characteristics of optical voltage transformer and its testing technology[J]. Electrical Measurement and Instrumentation, 2016, 53(4): 84-89.
QuShanshan, HeZhiwei. Research of magnetic field measurements based on Hall effect[J]. Electrical Measurement and Instrumentation, 2013, 50(10): 98-101.
XiangQiong, YueChangxi, HuChen, et al. Hall effect element array based current measurement system[J]. Electrical Measurement and Instrumentation, 2017, 54(23): 98-101.
LiTianyou, WangChao, ChenMinwei, et al. Analysis of typical earth faults example and transient feeder selection technology in the nonsolidly earthed system[J]. Electrical Measurement and Instrumentation, 2019, 56(2): 116-122.
CuiWeicheng, YangLibin, LiuLinmi, et al. Broadband multiresolution singular value decomposition denoising method based on energy criterion[J]. Science Technology and Engineering, 2026, 26(4): 1537-1548.