A tensile test was conducted on a composite stringer run-out specimen incorporating crack-arresting fasteners. Using the ABAQUS platform, finite element models were developed to simulate pre-existing debonding at the stringer-skin interface within the bolted run-out region. The bolted reinforcement area was modeled using GBJM (global bolted joint model). The influence of the pre-debonded area on interface damage initiation and the structure’s load-carrying capacity were analyzed. Furthermore, the load transfer mechanism of the arrest fasteners during structural failure was investigated. The results indicate that interface failure in the stringer run-out under tensile loading results from the combined action of out-of-plane peel stress and interlaminar shear stress. Fasteners located in the intact region of the stringer-skin interface carry negligible load. However, once debonding occurs, these fasteners begin to engage and transfer load. The extent of the bonded area at the stringer-skin interface primarily affects the damage initiation load but has little influence on the ultimate failure load of the structure. The first fastener row acts as the primary load-bearing element, upon failure of the structure surrounding its bolt holes, the load it carries drops sharply, accompanied by a significant increase in the load transferred by the second fastener row.
FalzonB G, DaviesG A O. The behavior of compressively loaded stiffener runout specimens-Part I: experiments[J]. Journal of Composite Materials, 2003, 37(5): 381-400.
[5]
CosentinoE, WeaverP M. Approximate non-linear analysis method for debonding of skin/stringer composite assemblies[J]. AIAA Journal, 2008, 46(5): 1144-1159.
[6]
CosentinoE, WeaverP M. A non-linear analytical approach for preliminary sizing of discrete composite stringer terminations[J]. AIAA Journal, 2009, 47(3): 606-617.
SongXin, LiWei, LiTong, et al. Load distribution law in multi-bolts connected composite structure[J]. Acta Materiae Compositae Sinica, 2024, 41(4): 2148-2156.
ChenLong, ChenPuhui. Load distribution and finite element analysis of composite-to-titanium hybrid structure with multiple-bolted joints[J]. Advances in Aeronautical Science and Engineering, 2020, 11(5): 679-685.
[23]
McCarthyM A, McCarthyC T, LawlorV P. Three-dimensional finite element analysis of single-bolt, single-lap composite bolted joints[J]. Composite Structures, 2005, 71(3/4): 159-171.
[24]
GrayP J, McCarthyC T. A global bolted joint model for finite element analysis of load distributions in multi-bolt composite joints[J]. Composites Part B, 2010, 41(4): 317-325.
[25]
ChenX M, ZhangJ. Evaluation of the bolted metallic repair on damaged stiffened composite panel[J]. Failure Analysis and Prevention, 2021, 21(3): 429-444.
[26]
Hosseini-ToudeshkyH, MohammadiB, HamidiB, et al. Analysis of composite skin/stiffener debonding and failure under uniaxial loading[J]. Composite Structures, 2006, 75(1/4): 428-436.
YangJunchao, ChaiYanan, ChenXiangming. Study on shear buckling and post-buckling behaviour of composite stiffened panels[J]. Science Technology and Engineering. 2019, 19(7): 289-293.
ZhangRu, ChaiYanan, ZhangAying, et al. Damage expansion of cap reinforced element with prefabricated delamination under four-point bending load[J]. Science Technology and Engineering, 2019, 19(10): 224-229.
[31]
IrwinG R. Analysis of stresses and strains near the end of a crack transversing a plate[J]. Journal of Applied Mechanics, 1957, 24(3): 361-364.
[32]
RybickiE F, KanninenM F. A finite element calculation of stress intensity factors by a modified crack integral[J]. Engineering Fracture Mechanics, 1977, 9(4): 931-938.
PengGuoliang, YanHui, DuTaijiao, et al. An error-correction analysis of virtual crack closure technique for mode I crack[J]. Chinese Journal of Solid Mechanics, 2016, 37(3): 280-283.
[35]
ASTM. Standard test method for bearing response of polymer matrix composite laminates: ASTM D5961/D5961M-13[S]. West Conshohocken: ASTM, 2013.