低温共烧陶瓷激光测厚系统设计与误差分析

张铮 ,  薛波 ,  金子博 ,  邱达河

科学技术与工程 ›› 2024, Vol. 24 ›› Issue (4) :1530-1537

PDF (2291KB)
科学技术与工程 ›› 2024, Vol. 24 ›› Issue (4) :1530-1537 DOI: 10.12404/j.issn.1671-1815.2302195
电子技术、通信技术

低温共烧陶瓷激光测厚系统设计与误差分析

作者信息 +

Design and Error Analysis of the LTCC Laser Thickness Measuring System

Author information +
文章历史 +

摘要

基于提升低温共烧陶瓷(low temperature co-fired ceramic, LTCC)厚度的检测精度、测量效率和可溯源性的需求,设计一套LTCC激光测厚系统。针对测量精度难以满足需求的问题,对存在误差进行分析,采用厚度测量用调整夹具消除同轴度误差和线性度误差,优化设计结构降低倾角误差,循环传感器标定消除重复度误差,通过数据优化和滤波处理降低机械振动误差,提高了系统测量精度。与实际产品厚度数据对比,最终精度误差≤5 μm,符合产品的应用要求,具有广阔的应用市场。

Abstract

Based on the need to improve the detection accuracy, efficiency and traceability of low temperature co-fired ceramics (LTCC), a set of LTCC laser thickness measuring system was designed. For the problem of measuring accuracy was difficult to meet, the existing error was analyzed, the use of adjusting fixture for thickness measurement eliminated coaxial error and linearity error, optimized the design structure to reduce inclination error, eliminated repeatability errors through cyclic sensor calibration, reduced mechanical vibration error through data optimization and filtering processing, improved the system measurement accuracy. Compared with the actual product thickness data, the final accuracy error ≤ 5 μm, which meets the application requirements of the product and has a broad application market.

引用本文

引用格式 ▾
张铮, 薛波, 金子博, 邱达河. 低温共烧陶瓷激光测厚系统设计与误差分析[J]. 科学技术与工程, 2024, 24(4): 1530-1537 DOI:10.12404/j.issn.1671-1815.2302195
ZHANG Zheng, XUE Bo, JIN Zi-bo, QIU Da-he. Design and Error Analysis of the LTCC Laser Thickness Measuring System[J]. Science Technology and Engineering, 2024, 24(4): 1530-1537 DOI:10.12404/j.issn.1671-1815.2302195