    摘要:

    针对严寒地区中深层地埋管换热器供暖时浅层出现的逆向换热问题,且长期运行导致的地下冷堆积和取热功率逐年衰减问题,本文建立了埋深2 000 m的同轴套管换热器二维轴对称数值模型,通过设置4种典型运行工况,对比分析了300 m浅层保温回填在自然恢复与太阳能跨季节蓄热两种模式下的5年长期换热特性,并探究了蓄热温度对系统效能的影响规律。结果表明:自然恢复模式下,浅层保温回填可减少浅层热量散失,使5年取热功率稳定提升2%以上,但无法从根本上解决岩土层热储衰减。蓄热流体温度为70 ℃时,太阳能跨季节蓄热可有效抑制热衰减,常规回填方案5年取热功率累计提升11.09%。从运行策略来看,由于浅层保温会降低蓄热功率,自然恢复工况宜采用浅层保温回填,蓄热工况优先选常规回填。研究结果可为严寒地区中深层地热能的可持续开发利用提供理论参考。

    Abstract:

    In severe cold regions, cold accumulation is caused by long-term heating-only operation of medium-deep ground source heat pumps, with shallow reverse heat exchange. with extractable thermal power reduced annually. A 2D axisymmetric numerical model of a 2000 m coaxial-casing deep borehole heat exchanger (DBHE) is developed. Four scenarios are compared over 5 years to evaluate the heat transfer performance of 300 m shallow insulated backfill under natural recovery and seasonal solar thermal storage, and examine the storage temperature effects on system efficiency. Under natural recovery, the heat extraction rate is increased by over 2% with insulated backfill, yet surrounding rock thermal degradation cannot be fully prevented. At a storage temperature of 70 ℃, thermal degradation is effectively mitigated by solar storage, with cumulative heat extraction for conventional backfill increased by 11.09%. Accordingly, Since shallow thermal insulation reduces the heat storage power, insulated backfill is recommended for natural recovery, while conventional backfill is preferable for storage-assisted operation. Theoretical support is provided for sustainable medium-deep geothermal development in severe cold regions.

    参考文献
    相似文献
    引证文献
引用本文

马成行,李吉鑫,王玉博. 严寒地区中深层地埋管浅层保温与蓄热特性分析[J]. 科学技术与工程, , ():

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-06-03
  • 最后修改日期:2026-09-04
  • 录用日期:2026-09-14
  • 在线发布日期:
  • 出版日期:
×
关于抵制伪造参考文献学术不端行为的声明
关于规范使用生成式人工智能的声明
喜报|《科学技术与工程》3篇论文成功入选 “第二十八届中国科协年会影响力提名论文”
2026年会通知 | “技术经济学驱动智能经济生态构建与治理变革”——中国技术经济学会第三十三届学术年会(2026)会议通知暨征文启事(第一轮)
亟待确认版面费归属稿件,敬请作者关注